New R.H. Transmitters THR Series, with capacitive or fiber dilation sensor. Dual 4-20 mA 2-wire RH% and ºT outputs. Available types for wall rooms, chambers or process mounting. Special types for high pressure and temperature. For all types of process applications. |
|
| |
- Relative Humidity and Temperature Transmitters
- Dual 4-20 mA 2-wire RH% and ºT outputs
- Capacitive or fiber dilation sensors
- Wall, chambers, process mounting models
- Special length and remote sensor Transmitters
- Special types for high temperature and pressure processes
- Hand held hygrometers with calculation of other variables
- Calibration kits and accessories.
|
|
|
| |
|
| TRH-30x Series uses a thin film polymer capacitor to sense Relative Humidity & a thin film RTD to accurately sense Temperature. The Output signal given is 4 - 20 mA analog output requiring a current loop supply of 1 2 - 30 VDC. The electronics is housed in a watertight IP-65 enclosure. |
|
| |
|
- Fast, Stable and accurate
- IP 65 - Watertight enclosure
- Excellent long term stability
- Onsfte two point calibration
|
|
| Typical Areas oi Application |
|
- Climatic Rooms/Chambers
- HVAC Installations
- Green Houses
- Paper Industries
- Incubators, Ovens
- Textile Industries
- Storage Area
- Food Processing Industries
- Fruit/Vegetable Storage
|
| |
Model |
DESCRIPTIONS |
TRH - 304 |
Humidity / Temperature Transmitter |
TRH - 305 |
Humidity Transmitter |
SHAPE (Mounting) |
W |
Wall Mount Type |
D |
Duct Mount Type |
S |
Separated Type |
|
| |
| Temperature & Humidity Transmitter |
| |
DO 9861 T humidity and temperature transmitters convert the humidity and temperature measured by two sensors into a 4-^20 mA signal.
An LCD indicator allows the value of the process Signal and the various parameters to be displayed.
The accurate design and choice of components make the instruments precise and reliable for a long working life. The instruments have two sensors, a capacitive sensor for measuring relative humidity and a Platinum resistive sensor [Ptl 00, 1 0012 at 1 00 C) for measuring temperature.
The transmitters measure the Relative Humidity (%RH), the sensor Temperature (TC), and Calculate the Wet Bulb Temperature (WT), the Dew Point Temperature (DP), the Absolute Humidity (gr/m3) and the Mixing Ratio [gr/kg - grams ofWaterperkg of dry air). The Temperatures are Expressed in Degrees Celsius. |
|
|
|
| |
| Technical Characteristics |
|
| |
Relative Humidity |
Capacity |
300 pF |
Transducer energizing |
10 kHz |
Cable length |
<. 10 m multiple screen (about 2 nFJ additional error about 0_003 pF/pF |
Accuracy |
ln*umert : 0.1% of reading ± 1 digit ±0_01%/C Sertor: ±2.3% (5...90%)r +3/-2_5% (90...98%J |
Working range of sensor |
Relative humidity- 5-98% @ 23°C Dew point temperature (DFC) -60^+100 DF°C (-20 DfC@ 23 °C) Temperature range : -40...+ 1 50 °C |
During use, check that the sensor is compatible with the atmosphere used |
Temperature |
2/4 wires Ft 100 |
-50___+199_9°C |
Transducer energizing |
0.5 mA dc |
Cable length |
<. 10m not screened <. 50 m screened (about 5 nFJ |
Accuracy |
0.2°C ±01% of reading ±001 °Q/*Q |
Output current A and B |
4rOO....2O,OO mA |
Dry bulb temperature -500 .+ 199-9 °C |
|
Wet bulb temperature -500 .+ 199-9 °C |
|
Relative humidity 00 _ + 100_0%RH |
|
Absolute humidity 0.0 .+ 1999 gr/m3 |
|
Mixing ratio 0.0... + 1 999 gr/Kg of air |
Accuracy |
±2.5% RH 0.5% of reading ±0.02 mA |
R- Load |
Load resistance |
^«=^ "-- = *36W@Vdc=24Vdc |
Relay Outputs |
A and B |
Biliable ewiharige contatl^ 3 A/230 Vat potential free conlacl |
Feed |
Ptissive |
4^-20 mA, 10...35Vdc |
Active |
24 or 230 Vac -15/+10%, 1 VA, 48 .62 Hz |
Response time |
Without filter |
6 seconds |
With filter |
3 minutes |
Case |
Front panel |
122 x 120 mm |
External dimensions |
122 x 120 x 56 mm |
Protection dass |
IP 64 |
|
| |
|
| |
DO 9861T |
: Two ouipuis 4 -r- 20 mA to n>easure relative humidity and temperature. |
DO 9861 TV/1 |
: VerficalfiaedprobeL = l30rnrn |
DO 9861 TO/2 |
: Horizontal probe L- 330 mm, sliding joint. |
DO 9861 TC/1 -2 |
: Probe L = 130 rnrn coble L = 2 meters. |
DO 9861 TC/2-5 |
: Probe L - 330 mm, sliding foini, coble L = |
DO 9861 TC/2-10 |
: Probe L = 330 mm, sliding joint, cable L = 10 meters. |
|
| |
| Model : HD2007 / 2008 |
| |
Description :
HD 2007T... & HD 2008T... ore microprocessor configurable humidity & configurable. ThiEy convErl humidity fi* temp, valise? into two linear current signals [2 wipes) in thiE field 4 -r-20mA_ In the hummity-tEmp_ combineri version, thiE two circuits £i the rElntED outputs dte complEtEly mnEpEnnEnt onEfromthE other. The linen runt ion bosefl on digital technique grant? best accuracy &*. stability: Programming is cnrriEn" out VEry Ensily by prEssmg n button. No opErntion by means of |umpErs; potentiomelErs; Etc. is requested- The humiqity input can be recnlibraIeh using two snturntEn solutions. thE first onE nt 75%thiE sEconn on&al 33%; thE 0% R.H...1 00% R.H.rElativEhummity range is fixEn £4 mA correspond to 0%R.H.; while 20mA to 100% R.H. In HD 2008 model 'he operator can configure 4-^20mA tEmp. output in any range going from -50QC up to I 200aC with 25QC minimum nmphtunE. A LED inmates the alarm statEs (tEmp. Exceeding set-pomtHSEnsorfailurE or short-circuit) £ hElpsthEopErat or when programming. |
|
|
|
| |
|
| |
Relative humidity Input |
|
HD20O7 |
HD2003 |
Model |
MK33 |
Capacity |
300 pF |
Accuracy at 20C |
±2% (5±m ±2 5% (in the remaining rarge) |
Relatiw humidity operating rarce |
5 98% RH |
Temperalure operatic rarKje of relative humidity sensor |
-40...+T 50"C - compensated |
Wirelerxjlh |
TC veision-1 5rn, 5rn aid 10m |
Working static pressure of sensor |
20 bar |
When using the Iransn atmos litter, check sensor compatibility with the here where iE is installed |
Temperature Input |
Sersor |
— |
Pt100.100£?at0flCf^00 00365l |
Connection |
— |
3for21wires |
Transd ucer ene razed |
— |
<1 mA |
Measurimrame |
— |
-50 +200C |
|
|
+01ci-0.1c readinq |
Output |
4...20mARH |
o..100% RH |
o..100% RH |
4...20mA Temperature |
— |
Confgiirable in tne lange-
50 200c |
22 mA |
In case of faulty/ programming, of discounnected probe or of temperature exceeding selected range
The alarm Led is lighted (*) |
|
|
Power supply for evejy jjpil |
7..30 Vdc |
Maximum load (see fig 3) |
(Vdc-7) ft..=770Ha24VdcR..= 22mA |
|
No filter With filter |
6 seconds
3 minutes |
Work temperature electronics |
-10..+70 c |
Eleclronics protection class |
IP 67 |
|
| |
|
| |
HD 2007TO/1: relative humidily 2-wire passive transmitter Dud horizontal fixed sensor L= 130mm.
HD 2007TV: relative humidHy 2-wire passive transmitter Wall-mounting vertical fixed sensor
HD 20D7TG/2-5: relative humidily 2-wire passive transmitter Sensor L=330 mm connected directly to the instrument by mean of a 5m longwire.
HD 2007TC/2-10: refcitive humidily 2-wire passive transmitter output. Sensor L=330mm connected directly to the instrument by means of a 1 Om long wire.
HD 2008TO/1: relative humidily and temperature dud configurable 2-wire passive combined transmitter Duct fixed horizontal sensor L= 130mm.
HD 2008TV: relative humidily and temperature duct configurable 2-wire passive combined transmitter Wall-mountin g fixed vertrcaf sensor
HD 2008TC/1: relative humidity and temperature dud configurable 2-wire passive combined transmitter Sensor L = l 30mm conneded diredly to the instrument by means of a 1.5m longwire.
HD 2OOBTC/2-5: relative humidily and temperature dud configurable 2-wire passive combined transmitter. Sensor L=330mm conneded directly to the instrument by means of a 5m longwire.
HD2008TC/2-10: relative humidily and temperature dud configurable 2-wire passive combined transmitter. Sensor L=330mm conneded diredly to the instrument by means of a 10m longwire. |
| |
| Conductivity Transmitter / Controller |
|
| |
DO 9786T / DO 9766T transmitters convert the output of a conductivity electrode into a signal, with temperature compensation, at 4 + 20mA.
The electrode input circuit is galvanically insulated against the 4 + 20mA output signal. An LCD indicator allows viewing of the process signal value and of the various parameters. The accurate design and choice of components make the instrument precise and reliable for a long working life.
The instrument works in conjunction with a conductivity electrode and a temperature probe (Pt100 sensor, 100 at OC). |
| |
Input Conductivity |
Measuring range |
0 0 .199.9 mS |
2/4 electrodes |
Configurable cell constant 0.01. 199.9 cm-1 |
Transducer Energizing |
Square wave 10 .1000 mV depending on Conductivity, 200...1600 Hz, Depending on Conductivity |
Input impedance |
> lOOMohm |
Cable length |
< 10 meters unscreened < 50 meters screened (about 2 nF} |
Accuracy |
0 5% of reading ±2 digits ± 0.0 J% per DCof drift in temperature |
Input Temperature |
F1100 2/4 wires |
-50.. 199.9CC |
Transducer Energizing |
0 5 rnAdc |
Cabfe Length |
<10 meters unscreened <50 meters screened (about 2 nF) |
Accuracy |
0.2cC ± 0 1% of reading ± 0.01°C/°C of drift in Temperature |
Compensation temperature |
None |
|
Manual |
Linear 0.00...4.00% / DC -50... + 200DC |
Automatic |
Linear 0.00.. 4.00% / "C -50...+ 200"C |
Reference Temp |
20 or 25°C Configurate |
Current
output |
4 00 .20.00 mA |
Programmable and Proportional to Conductivity |
Accuracy |
0 5% of reading ± 0.02 mA |
Insulation |
2500 Vac 1 minute |
Relay output |
A and B |
Bistable, contact 3A/230 Vac free potential |
Power
Supply |
Passive |
4- 20mA 2 wire configuration, 10-35V, see Jig 2 |
Active |
24/230 Vac -15/+10% 1 VA, 48. 62 Hz, see fig 1 |
Case DO 9766 T |
External dimensions |
120 X 122 X 56 mm |
Protection class |
IP64 |
Case DO 9786 T |
External dimensions |
96 X 96 X T26 mm |
Protection class |
IP44 |
|
| |
|
| |
DO9786T : Conductivity transmitter 4-20 rnA passive or active, power supply 24 Vac with double display 96*96 mm, for panel mounting.
DO9766T : Conductivity transmitter 4-20 rnA passive or active, power supply 24 Vac with double display 122x12Dmrn,foruseonthefield. |
| |